发布时间 : 2026-04-10 07:27:10 UTC
类别 : Classic physics
Page Views: 555 views
Enter the value and click "Calculate" to display the result
Calculation formula:

fT = Turbulent friction factor
L = length
D = pipe diameter
K = K value
Input data:
Turbulent friction factor: 45
Length: 60m
Pipe diameter: 10mm
Click "Calculate" to output data
K value: 270.000
This calculator calculates the tube diameter change, the K
value of the L/D coefficient valve. The L/D
factor is stored in the valve table for the tube diameter range.
These valves are butterfly valves and swash plate type check valves.